USAfixTM - Repair Guide (RG) - Master Email RG
- Check solution flow from the pump.
 Level of Difficulty - MEDIUM  Estimated Completion Time - 20 minutes
TASKI - SWINGO 350B

Tools Required
Tool 
Torx T30

Parts Required


Step Procedure & Parts & Tools
1 LIFT THE RECOVERY TANK FROM THE MACHINE.

2 RAISE THE TANK COVER UP UNTIL IT POPS OFF MACHINE.

3 LOCATE THE 2 HOSES COMING UP THRU THE SOLUTION TANK. PULL THE 2 HOSES CUFFS OFF HOSES.

4 REMOVE THE 2 BOLTS IN THE BATTERY COMPARTMENT.
Torx T30

5 LOOSEN THE BOLT ON THE FRONT OF THE SOLUTION TANK.
Torx T30

6 REMOVE THE 2 SOLUTION TANK BOLTS ON EACH SIDE OF THE TANK.
Torx T30

7 PULL THE TANK UP TO RAISE IT.

8 TURN THE POWER ON AND THE SOLUTION ON.

9 PULL THE HOSE FROM THE FRONT OF THE SOLUTION PUMP. (THE HOSE CLOSEST TO THE VAC MOTOR). IF SOLUTION COMES OUT OF THE PUMP, THE FLOW IS OKAY.

10 IF THE SOLUTION FLOW IS OKAY, REVERSE STEPS 1 THRU 9 TO REASSEMBLE THE MACHINE.